Name: Switch
Display Field: FacilityID
Type: Feature Layer
Geometry Type: esriGeometryPoint
Description:
Service Item Id: 5142a10118a5497b874461db39dd501b
Copyright Text:
Default Visibility: true
MaxRecordCount: 1000
Supported Query Formats: JSON, geoJSON, PBF
Min Scale: 5000.000000000198
Max Scale: 0
Supports Advanced Queries: true
Supports Statistics: true
Has Labels: false
Can Modify Layer: true
Can Scale Symbols: false
Use Standardized Queries: true
Supports Datum Transformation: true
Extent:
XMin: 2338437.0720644966
YMin: 1428162.4999459088
XMax: 2434635.6237614937
YMax: 1457977.4373631552
Spatial Reference: 102667
(2240)
Drawing Info:
Renderer:
Unique Value Renderer:
Field 1: SubtypeCD
Field 2: NormalPosition_A
Field 3: N/A
Field Delimiter: ,
Default Symbol:
Default Label: N/A
UniqueValueInfos:
-
Value: 4,1
Label: Flip Flop - Underground Closed
Description: N/A
Symbol:
-
Value: 4,0
Label: Flip Flop - Underground Open
Description: N/A
Symbol:
-
Value: 2,1
Label: Gang Switch - Closed
Description: N/A
Symbol:
-
Value: 2,0
Label: Gang Switch - Open
Description: N/A
Symbol:
-
Value: 1,1
Label: Isolating Switch, Closed
Description: N/A
Symbol:
-
Value: 5,1
Label: Underslung, Closed
Description: N/A
Symbol:
-
Value: 5,0
Label: Underslung, Open
Description: N/A
Symbol:
Transparency: 0
Labeling Info:
Advanced Query Capabilities:
Supports Statistics: true
Supports OrderBy: true
Supports Distinct: true
Supports Pagination: true
Supports TrueCurve: true
Supports Returning Query Extent: true
Supports Query With Distance: true
Supports Sql Expression: true
Supports Query With ResultType: false
Supports Returning Geometry Centroid: false
Supports Binning LOD: false
Supports Query With LOD Spatial Reference: false
HasZ: false
HasM: false
Has Attachments: true
HTML Popup Type: esriServerHTMLPopupTypeAsHTMLText
Type ID Field: SubtypeCD
Fields:
-
OBJECTID
(
type: esriFieldTypeOID, alias: OBJECTID
)
-
AncillaryRole
(
type: esriFieldTypeSmallInteger, alias: AncillaryRole
)
-
Enabled
(
type: esriFieldTypeSmallInteger, alias: Enabled
, Coded Values:
[0: False]
, [1: True]
)
-
SubtypeCD
(
type: esriFieldTypeInteger, alias: Subtype
)
-
FacilityID
(
type: esriFieldTypeString, alias: Facility ID, length: 20
)
-
FeederID
(
type: esriFieldTypeString, alias: Feeder ID, length: 20
, Coded Values:
[0502: 0502]
, [0512: 0512]
, [0522: 0522]
, ...14 more...
)
-
FeederID2
(
type: esriFieldTypeString, alias: Feeder ID 2, length: 20
, Coded Values:
[0502: 0502]
, [0512: 0512]
, [0522: 0522]
, ...14 more...
)
-
ConstructionStatus
(
type: esriFieldTypeInteger, alias: Construction Status
, Coded Values:
[0: Proposed]
, [5: Existing]
, [10: Waiting For Staking]
, ...5 more...
)
-
WorkOrderID
(
type: esriFieldTypeString, alias: Work Order ID, length: 20
)
-
InstallationDate
(
type: esriFieldTypeDate, alias: Installation Date, length: 8
)
-
Comments
(
type: esriFieldTypeString, alias: Comments, length: 255
)
-
ElectricTraceWeight
(
type: esriFieldTypeInteger, alias: Electric Trace Weight
)
-
FeederInfo
(
type: esriFieldTypeInteger, alias: Feeder Information
)
-
SymbolRotation
(
type: esriFieldTypeDouble, alias: Symbol Rotation
)
-
Hyperlink
(
type: esriFieldTypeString, alias: Hyperlink, length: 255
)
-
NominalVoltage
(
type: esriFieldTypeInteger, alias: NominalVoltage
)
-
PhaseDesignation
(
type: esriFieldTypeInteger, alias: Phase Designation
)
-
ManuallyOperated
(
type: esriFieldTypeString, alias: Manually Operated Indicator, length: 5
)
-
MaxContinuousCurrent
(
type: esriFieldTypeDouble, alias: Maximum Continuous Current
)
-
MaxOperatingVoltage
(
type: esriFieldTypeInteger, alias: Maximum Operating Voltage
, Coded Values:
[160: 4.16/7.2 kV]
, [210: 7.2/12.4 kV]
, [230: 7.6/13.2 kV]
, ...3 more...
)
-
NormalPosition_A
(
type: esriFieldTypeInteger, alias: Normal Position - A
, Coded Values:
[1: Closed]
, [0: Open]
, [2: Not Applicable]
)
-
NormalPosition_B
(
type: esriFieldTypeInteger, alias: Normal Position - B
, Coded Values:
[1: Closed]
, [0: Open]
, [2: Not Applicable]
)
-
NormalPosition_C
(
type: esriFieldTypeInteger, alias: Normal Position - C
, Coded Values:
[1: Closed]
, [0: Open]
, [2: Not Applicable]
)
-
PresentPosition_A
(
type: esriFieldTypeInteger, alias: Present Position - A
, Coded Values:
[1: Closed]
, [0: Open]
, [2: Not Applicable]
)
-
PresentPosition_B
(
type: esriFieldTypeInteger, alias: Present Position - B
, Coded Values:
[1: Closed]
, [0: Open]
, [2: Not Applicable]
)
-
PresentPosition_C
(
type: esriFieldTypeInteger, alias: Present Position - C
, Coded Values:
[1: Closed]
, [0: Open]
, [2: Not Applicable]
)
-
TieSwitchIndicator
(
type: esriFieldTypeString, alias: Tie Switch Indicator, length: 5
)
-
SCADAControlID
(
type: esriFieldTypeString, alias: SCADA Control ID, length: 20
)
-
SCADAMonitorID
(
type: esriFieldTypeString, alias: SCADA Monitor ID, length: 20
)
-
PreferredCircuitSource
(
type: esriFieldTypeString, alias: Preferred Circuit Source, length: 20
)
-
LabelText
(
type: esriFieldTypeString, alias: Label Text, length: 50
)
-
SupportStructureObjectID
(
type: esriFieldTypeInteger, alias: SupportStructureObjectID
)
-
GangOperated
(
type: esriFieldTypeString, alias: Gang Operated Indicator, length: 5
)
-
HFrameObjectID
(
type: esriFieldTypeInteger, alias: H Frame ObjectID
)
-
SwitchingFacilityObjectID
(
type: esriFieldTypeInteger, alias: Switching Facility ObjectID
)
-
UndergroundStructureObjectID
(
type: esriFieldTypeInteger, alias: Underground Structure ObjectID
)
-
OPERATINGCLASS
(
type: esriFieldTypeString, alias: OPERATINGCLASS, length: 50
)
-
CONSTRUCTIONTYPE
(
type: esriFieldTypeString, alias: CONSTRUCTIONTYPE, length: 50
)
-
DeviceGUID
(
type: esriFieldTypeGUID, alias: Device GUID, length: 38
)
-
Shape
(
type: esriFieldTypeGeometry, alias: Shape
)
-
created_user
(
type: esriFieldTypeString, alias: created_user, length: 255
)
-
created_date
(
type: esriFieldTypeDate, alias: created_date, length: 8
)
-
last_edited_user
(
type: esriFieldTypeString, alias: last_edited_user, length: 255
)
-
last_edited_date
(
type: esriFieldTypeDate, alias: last_edited_date, length: 8
)
-
GlobalID
(
type: esriFieldTypeGlobalID, alias: GlobalID, length: 38
)
Types:
ID: 3
Name: Underground Disconnect
Domains:
-
Enabled:
Inherited
-
ConstructionStatus:
Inherited
-
NominalVoltage:
Coded Values:
[120: 4.16 kV Grounded Wye]
, [160: 7.2 kV Grounded Wye]
, [230: 13.2 kV Grounded Wye]
, ...9 more...
-
PhaseDesignation:
Coded Values:
[4: A]
, [6: AB]
, [5: AC]
, ...4 more...
-
ManuallyOperated:
Coded Values:
[N: No]
, [Y: Yes]
-
MaxContinuousCurrent:
Coded Values:
[50: 50 A]
, [100: 100 A]
, [200: 200 A]
, ...5 more...
-
MaxOperatingVoltage:
Inherited
-
NormalPosition_A:
Inherited
-
NormalPosition_B:
Inherited
-
NormalPosition_C:
Inherited
-
PresentPosition_A:
Inherited
-
PresentPosition_B:
Inherited
-
PresentPosition_C:
Inherited
-
TieSwitchIndicator:
Coded Values:
[N: No]
, [Y: Yes]
-
GangOperated:
Coded Values:
[N: No]
, [Y: Yes]
ID: 2
Name: Gang Switch - Overhead Load Break
Domains:
-
Enabled:
Inherited
-
ConstructionStatus:
Inherited
-
NominalVoltage:
Coded Values:
[120: 4.16 kV Grounded Wye]
, [160: 7.2 kV Grounded Wye]
, [230: 13.2 kV Grounded Wye]
, ...9 more...
-
PhaseDesignation:
Coded Values:
[4: A]
, [6: AB]
, [5: AC]
, ...4 more...
-
ManuallyOperated:
Coded Values:
[N: No]
, [Y: Yes]
-
MaxContinuousCurrent:
Coded Values:
[50: 50 A]
, [100: 100 A]
, [200: 200 A]
, ...5 more...
-
MaxOperatingVoltage:
Inherited
-
NormalPosition_A:
Inherited
-
NormalPosition_B:
Inherited
-
NormalPosition_C:
Inherited
-
PresentPosition_A:
Inherited
-
PresentPosition_B:
Inherited
-
PresentPosition_C:
Inherited
-
TieSwitchIndicator:
Coded Values:
[N: No]
, [Y: Yes]
-
GangOperated:
Coded Values:
[N: No]
, [Y: Yes]
ID: 4
Name: Flip Flop - Underground Load Break
Domains:
-
Enabled:
Inherited
-
ConstructionStatus:
Inherited
-
NominalVoltage:
Coded Values:
[120: 4.16 kV Grounded Wye]
, [160: 7.2 kV Grounded Wye]
, [230: 13.2 kV Grounded Wye]
, ...9 more...
-
PhaseDesignation:
Coded Values:
[4: A]
, [6: AB]
, [5: AC]
, ...4 more...
-
ManuallyOperated:
Coded Values:
[N: No]
, [Y: Yes]
-
MaxContinuousCurrent:
Coded Values:
[50: 50 A]
, [100: 100 A]
, [200: 200 A]
, ...5 more...
-
MaxOperatingVoltage:
Inherited
-
NormalPosition_A:
Inherited
-
NormalPosition_B:
Inherited
-
NormalPosition_C:
Inherited
-
PresentPosition_A:
Inherited
-
PresentPosition_B:
Inherited
-
PresentPosition_C:
Inherited
-
TieSwitchIndicator:
Coded Values:
[N: No]
, [Y: Yes]
-
GangOperated:
Coded Values:
[N: No]
, [Y: Yes]
ID: 1
Name: Isolating Switch
Domains:
-
Enabled:
Inherited
-
ConstructionStatus:
Inherited
-
NominalVoltage:
Coded Values:
[120: 4.16 kV Grounded Wye]
, [160: 7.2 kV Grounded Wye]
, [230: 13.2 kV Grounded Wye]
, ...9 more...
-
PhaseDesignation:
Coded Values:
[4: A]
, [6: AB]
, [5: AC]
, ...4 more...
-
ManuallyOperated:
Coded Values:
[N: No]
, [Y: Yes]
-
MaxContinuousCurrent:
Coded Values:
[50: 50 A]
, [100: 100 A]
, [200: 200 A]
, ...5 more...
-
MaxOperatingVoltage:
Inherited
-
NormalPosition_A:
Inherited
-
NormalPosition_B:
Inherited
-
NormalPosition_C:
Inherited
-
PresentPosition_A:
Inherited
-
PresentPosition_B:
Inherited
-
PresentPosition_C:
Inherited
-
TieSwitchIndicator:
Coded Values:
[N: No]
, [Y: Yes]
-
GangOperated:
Coded Values:
[N: No]
, [Y: Yes]
ID: 5
Name: Underslung
Domains:
-
Enabled:
Inherited
-
ConstructionStatus:
Inherited
-
NominalVoltage:
Coded Values:
[120: 4.16 kV Grounded Wye]
, [160: 7.2 kV Grounded Wye]
, [230: 13.2 kV Grounded Wye]
, ...9 more...
-
PhaseDesignation:
Coded Values:
[4: A]
, [6: AB]
, [5: AC]
, ...4 more...
-
ManuallyOperated:
Coded Values:
[N: No]
, [Y: Yes]
-
MaxContinuousCurrent:
Coded Values:
[50: 50 A]
, [100: 100 A]
, [200: 200 A]
, ...5 more...
-
MaxOperatingVoltage:
Inherited
-
NormalPosition_A:
Inherited
-
NormalPosition_B:
Inherited
-
NormalPosition_C:
Inherited
-
PresentPosition_A:
Inherited
-
PresentPosition_B:
Inherited
-
PresentPosition_C:
Inherited
Supported Operations:
Query
Query Attachments
Query Analytic
Generate Renderer
Return Updates
Iteminfo
Thumbnail
Metadata