Name: Dynamic Protective Device
Display Field: FacilityID
Type: Feature Layer
Geometry Type: esriGeometryPoint
Description:
Service Item Id: 5142a10118a5497b874461db39dd501b
Copyright Text:
Default Visibility: true
MaxRecordCount: 1000
Supported Query Formats: JSON, geoJSON, PBF
Min Scale: 5000.000000000218
Max Scale: 0
Supports Advanced Queries: true
Supports Statistics: true
Has Labels: false
Can Modify Layer: true
Can Scale Symbols: false
Use Standardized Queries: true
Supports Datum Transformation: true
Extent:
XMin: 2340813.5935581625
YMin: 1433695.9737870693
XMax: 2360611.9273209944
YMax: 1446177.0078800693
Spatial Reference: 102667
(2240)
Drawing Info:
Renderer:
Unique Value Renderer:
Field 1: SubtypeCD
Field 2: N/A
Field 3: N/A
Field Delimiter: ,
Default Symbol: Style: esriSMSCircle
Color: [0, 153, 145, 255]
Size: 4.0
Angle: 0.0
XOffset: 0
YOffset: 0
Outline:
Default Label:
UniqueValueInfos:
-
Value: 1
Label: Circuit Breaker
Description: N/A
Symbol:
-
Value: 2
Label: Fault Interrupter
Description: N/A
Symbol:
-
Value: 3
Label: Single Phase Hydraulic Recloser
Description: N/A
Symbol:
-
Value: 8
Label: Single Phase Hydraulic Sectionalizer
Description: N/A
Symbol:
-
Value: 6
Label: Three Phase Electronic Recloser
Description: N/A
Symbol:
-
Value: 11
Label: Three Phase Electronic Sectionalizer
Description: N/A
Symbol:
-
Value: 5
Label: Three Phase Hydraulic Recloser
Description: N/A
Symbol:
-
Value: 10
Label: Three Phase Hydraulic Sectionalizer
Description: N/A
Symbol:
-
Value: 7
Label: Three Phase Relay Recloser
Description: N/A
Symbol:
-
Value: 4
Label: Two Phase Hydraulic Recloser
Description: N/A
Symbol:
-
Value: 9
Label: Two Phase Hydraulic Sectionalizer
Description: N/A
Symbol:
Transparency: 0
Labeling Info:
Advanced Query Capabilities:
Supports Statistics: true
Supports OrderBy: true
Supports Distinct: true
Supports Pagination: true
Supports TrueCurve: true
Supports Returning Query Extent: true
Supports Query With Distance: true
Supports Sql Expression: true
Supports Query With ResultType: false
Supports Returning Geometry Centroid: false
Supports Binning LOD: false
Supports Query With LOD Spatial Reference: false
HasZ: false
HasM: false
Has Attachments: true
HTML Popup Type: esriServerHTMLPopupTypeAsHTMLText
Type ID Field: SubtypeCD
Fields:
-
OBJECTID
(
type: esriFieldTypeOID, alias: OBJECTID
)
-
AncillaryRole
(
type: esriFieldTypeSmallInteger, alias: AncillaryRole
, Coded Values:
[0: None]
, [1: Source]
, [2: Sink]
)
-
Enabled
(
type: esriFieldTypeSmallInteger, alias: Enabled
, Coded Values:
[0: False]
, [1: True]
)
-
SubtypeCD
(
type: esriFieldTypeInteger, alias: Subtype
)
-
FacilityID
(
type: esriFieldTypeString, alias: Facility ID, length: 20
)
-
FeederID
(
type: esriFieldTypeString, alias: Feeder ID, length: 20
, Coded Values:
[0502: 0502]
, [0512: 0512]
, [0522: 0522]
, ...14 more...
)
-
ConstructionStatus
(
type: esriFieldTypeInteger, alias: Construction Status
, Coded Values:
[0: Proposed]
, [5: Existing]
, [10: Waiting For Staking]
, ...5 more...
)
-
WorkOrderID
(
type: esriFieldTypeString, alias: Work Order ID, length: 20
)
-
InstallationDate
(
type: esriFieldTypeDate, alias: Installation Date, length: 8
)
-
Comments
(
type: esriFieldTypeString, alias: Comments, length: 255
)
-
ElectricTraceWeight
(
type: esriFieldTypeInteger, alias: Electric Trace Weight
)
-
FeederInfo
(
type: esriFieldTypeInteger, alias: Feeder Information
)
-
SymbolRotation
(
type: esriFieldTypeDouble, alias: Symbol Rotation
)
-
Hyperlink
(
type: esriFieldTypeString, alias: Hyperlink, length: 255
)
-
NominalVoltage
(
type: esriFieldTypeInteger, alias: NominalVoltage
)
-
MaxContinuousCurrent
(
type: esriFieldTypeDouble, alias: Maximum Continuous Current
, Coded Values:
[50: 50 A]
, [100: 100 A]
, [200: 200 A]
, ...7 more...
)
-
MaxInterruptingCurrent
(
type: esriFieldTypeDouble, alias: Maximum Interrupting Current
, Coded Values:
[2500: 2.5 kA]
, [4000: 4 kA]
, [6000: 6 kA]
, ...10 more...
)
-
MaxOperatingVoltage
(
type: esriFieldTypeInteger, alias: Maximum Operating Voltage
, Coded Values:
[160: 4.16/7.2 kV]
, [210: 7.2/12.4 kV]
, [230: 7.6/13.2 kV]
, ...3 more...
)
-
NormalPosition_A
(
type: esriFieldTypeInteger, alias: Normal Position - A
, Coded Values:
[1: Closed]
, [0: Open]
, [2: Not Applicable]
)
-
NormalPosition_B
(
type: esriFieldTypeInteger, alias: Normal Position - B
, Coded Values:
[1: Closed]
, [0: Open]
, [2: Not Applicable]
)
-
NormalPosition_C
(
type: esriFieldTypeInteger, alias: Normal Position - C
, Coded Values:
[1: Closed]
, [0: Open]
, [2: Not Applicable]
)
-
PresentPosition_A
(
type: esriFieldTypeInteger, alias: Present Position - A
, Coded Values:
[1: Closed]
, [0: Open]
, [2: Not Applicable]
)
-
PresentPosition_B
(
type: esriFieldTypeInteger, alias: Present Position - B
, Coded Values:
[1: Closed]
, [0: Open]
, [2: Not Applicable]
)
-
PresentPosition_C
(
type: esriFieldTypeInteger, alias: Present Position - C
, Coded Values:
[1: Closed]
, [0: Open]
, [2: Not Applicable]
)
-
LabelText
(
type: esriFieldTypeString, alias: Label Text, length: 50
)
-
PhaseDesignation
(
type: esriFieldTypeInteger, alias: Phase Designation
)
-
BILRating
(
type: esriFieldTypeInteger, alias: BIL Rating
, Coded Values:
[95: 95 BIL]
, [110: 110 BIL]
, [125: 125 BIL]
, ...4 more...
)
-
BypassSwitch
(
type: esriFieldTypeString, alias: Bypass Switch, length: 5
)
-
GangOperated
(
type: esriFieldTypeString, alias: Gang Operated Indicator, length: 5
)
-
GroundResistance
(
type: esriFieldTypeDouble, alias: Ground Resistance
)
-
InterruptingMechanism
(
type: esriFieldTypeString, alias: Interrupting Mechanism, length: 20
)
-
InterruptingMedium
(
type: esriFieldTypeString, alias: Interrupting Medium, length: 5
, Coded Values:
[AIR: Air]
, [OIL: Oil]
, [PUF: Puffer]
, ...3 more...
)
-
MountingType
(
type: esriFieldTypeString, alias: Mounting Type, length: 5
)
-
SCADAControlID
(
type: esriFieldTypeString, alias: SCADA Control ID, length: 20
)
-
SCADAMonitorID
(
type: esriFieldTypeString, alias: SCADA Monitor ID, length: 20
)
-
ShuntMechanism
(
type: esriFieldTypeString, alias: Shunt Mechanism, length: 20
)
-
TieSwitchIndicator
(
type: esriFieldTypeString, alias: Tie Switch Indicator, length: 5
)
-
TripCount
(
type: esriFieldTypeInteger, alias: Trip Count
)
-
Manufacturer
(
type: esriFieldTypeString, alias: Manufacturer, length: 25
)
-
Model
(
type: esriFieldTypeString, alias: Model, length: 20
)
-
SerialNumber
(
type: esriFieldTypeString, alias: Serial Number, length: 20
)
-
SupportStructureObjectID
(
type: esriFieldTypeInteger, alias: SupportStructureObjectID
)
-
HFrameObjectID
(
type: esriFieldTypeInteger, alias: H Frame ObjectID
)
-
ElectricStationObjectID
(
type: esriFieldTypeInteger, alias: Electric Station ObjectID
)
-
SwitchingFacilityObjectID
(
type: esriFieldTypeInteger, alias: Switching Facility ObjectID
)
-
OWNER
(
type: esriFieldTypeString, alias: OWNER, length: 50
)
-
OPERATINGCLASS
(
type: esriFieldTypeString, alias: OPERATINGCLASS, length: 50
)
-
CONSTRUCTIONTYPE
(
type: esriFieldTypeString, alias: CONSTRUCTIONTYPE, length: 50
)
-
FUSESIZE
(
type: esriFieldTypeString, alias: FUSESIZE, length: 50
)
-
DeviceGUID
(
type: esriFieldTypeGUID, alias: Device GUID, length: 38
)
-
Shape
(
type: esriFieldTypeGeometry, alias: Shape
)
-
created_user
(
type: esriFieldTypeString, alias: created_user, length: 255
)
-
created_date
(
type: esriFieldTypeDate, alias: created_date, length: 8
)
-
last_edited_user
(
type: esriFieldTypeString, alias: last_edited_user, length: 255
)
-
last_edited_date
(
type: esriFieldTypeDate, alias: last_edited_date, length: 8
)
-
GlobalID
(
type: esriFieldTypeGlobalID, alias: GlobalID, length: 38
)
Types:
ID: 8
Name: Single Phase Hydraulic Sectionalizer
Domains:
-
AncillaryRole:
Inherited
-
Enabled:
Inherited
-
FeederID:
Inherited
-
ConstructionStatus:
Inherited
-
NominalVoltage:
Coded Values:
[70: 2.4 kV]
, [290: 14.4 kV]
, [330: 24.9 kV]
, ...1 more...
-
MaxContinuousCurrent:
Inherited
-
MaxInterruptingCurrent:
Inherited
-
MaxOperatingVoltage:
Inherited
-
NormalPosition_A:
Inherited
-
NormalPosition_B:
Inherited
-
NormalPosition_C:
Inherited
-
PresentPosition_A:
Inherited
-
PresentPosition_B:
Inherited
-
PresentPosition_C:
Inherited
-
PhaseDesignation:
Coded Values:
[4: A]
, [2: B]
, [1: C]
-
BILRating:
Inherited
-
BypassSwitch:
Coded Values:
[NA: Not Applicable]
-
GangOperated:
Coded Values:
[NA: Not Applicable]
-
InterruptingMedium:
Inherited
-
MountingType:
Coded Values:
[NA: Not Applicable]
-
ShuntMechanism:
Coded Values:
[NA: Not Applicable]
-
TieSwitchIndicator:
Coded Values:
[NA: Not Applicable]
-
TripCount:
Coded Values:
[0: Not Applicable]
ID: 11
Name: Three Phase Electronic Sectionalizer
Domains:
-
AncillaryRole:
Inherited
-
Enabled:
Inherited
-
FeederID:
Inherited
-
ConstructionStatus:
Inherited
-
NominalVoltage:
Coded Values:
[70: 2.4 kV]
, [290: 14.4 kV]
, [330: 24.9 kV]
, ...1 more...
-
MaxContinuousCurrent:
Inherited
-
MaxInterruptingCurrent:
Inherited
-
MaxOperatingVoltage:
Inherited
-
NormalPosition_A:
Inherited
-
NormalPosition_B:
Inherited
-
NormalPosition_C:
Inherited
-
PresentPosition_A:
Inherited
-
PresentPosition_B:
Inherited
-
PresentPosition_C:
Inherited
-
PhaseDesignation:
Coded Values:
[7: ABC]
-
BILRating:
Inherited
-
BypassSwitch:
Coded Values:
[NA: Not Applicable]
-
GangOperated:
Coded Values:
[NA: Not Applicable]
-
InterruptingMedium:
Inherited
-
MountingType:
Coded Values:
[NA: Not Applicable]
-
ShuntMechanism:
Coded Values:
[NA: Not Applicable]
-
TieSwitchIndicator:
Coded Values:
[NA: Not Applicable]
-
TripCount:
Coded Values:
[0: Not Applicable]
ID: 5
Name: Three Phase Hydraulic Recloser
Domains:
-
AncillaryRole:
Inherited
-
Enabled:
Inherited
-
FeederID:
Inherited
-
ConstructionStatus:
Inherited
-
NominalVoltage:
Coded Values:
[100: 4.16 kV]
, [290: 14.4 kV]
, [330: 24.9 kV]
, ...1 more...
-
MaxContinuousCurrent:
Inherited
-
MaxInterruptingCurrent:
Inherited
-
MaxOperatingVoltage:
Inherited
-
NormalPosition_A:
Inherited
-
NormalPosition_B:
Inherited
-
NormalPosition_C:
Inherited
-
PresentPosition_A:
Inherited
-
PresentPosition_B:
Inherited
-
PresentPosition_C:
Inherited
-
PhaseDesignation:
Coded Values:
[7: ABC]
-
BILRating:
Inherited
-
BypassSwitch:
Coded Values:
[N: No]
, [Y: Yes]
-
GangOperated:
Coded Values:
[NA: Not Applicable]
-
InterruptingMedium:
Inherited
-
MountingType:
Coded Values:
[PAD: Pad Mounted]
, [POL: Pole Mounted]
, [SUB: Substation Frame]
-
ShuntMechanism:
Coded Values:
[NA: Not Applicable]
-
TieSwitchIndicator:
Coded Values:
[N: No]
, [Y: Yes]
-
TripCount:
Coded Values:
[0: Not Applicable]
ID: 9
Name: Two Phase Hydraulic Sectionalizer
Domains:
-
AncillaryRole:
Inherited
-
Enabled:
Inherited
-
FeederID:
Inherited
-
ConstructionStatus:
Inherited
-
NominalVoltage:
Coded Values:
[70: 2.4 kV]
, [290: 14.4 kV]
, [330: 24.9 kV]
, ...1 more...
-
MaxContinuousCurrent:
Inherited
-
MaxInterruptingCurrent:
Inherited
-
MaxOperatingVoltage:
Inherited
-
NormalPosition_A:
Inherited
-
NormalPosition_B:
Inherited
-
NormalPosition_C:
Inherited
-
PresentPosition_A:
Inherited
-
PresentPosition_B:
Inherited
-
PresentPosition_C:
Inherited
-
PhaseDesignation:
Coded Values:
[6: AB]
, [5: AC]
, [3: BC]
-
BILRating:
Inherited
-
BypassSwitch:
Coded Values:
[NA: Not Applicable]
-
GangOperated:
Coded Values:
[NA: Not Applicable]
-
InterruptingMedium:
Inherited
-
MountingType:
Coded Values:
[NA: Not Applicable]
-
ShuntMechanism:
Coded Values:
[NA: Not Applicable]
-
TieSwitchIndicator:
Coded Values:
[NA: Not Applicable]
-
TripCount:
Coded Values:
[0: Not Applicable]
ID: 10
Name: Three Phase Hydraulic Sectionalizer
Domains:
-
AncillaryRole:
Inherited
-
Enabled:
Inherited
-
FeederID:
Inherited
-
ConstructionStatus:
Inherited
-
NominalVoltage:
Coded Values:
[70: 2.4 kV]
, [290: 14.4 kV]
, [330: 24.9 kV]
, ...1 more...
-
MaxContinuousCurrent:
Inherited
-
MaxInterruptingCurrent:
Inherited
-
MaxOperatingVoltage:
Inherited
-
NormalPosition_A:
Inherited
-
NormalPosition_B:
Inherited
-
NormalPosition_C:
Inherited
-
PresentPosition_A:
Inherited
-
PresentPosition_B:
Inherited
-
PresentPosition_C:
Inherited
-
PhaseDesignation:
Coded Values:
[7: ABC]
-
BILRating:
Inherited
-
BypassSwitch:
Coded Values:
[NA: Not Applicable]
-
GangOperated:
Coded Values:
[NA: Not Applicable]
-
InterruptingMedium:
Inherited
-
MountingType:
Coded Values:
[NA: Not Applicable]
-
ShuntMechanism:
Coded Values:
[NA: Not Applicable]
-
TieSwitchIndicator:
Coded Values:
[NA: Not Applicable]
-
TripCount:
Coded Values:
[0: Not Applicable]
ID: 6
Name: Three Phase Electronic Recloser
Domains:
-
AncillaryRole:
Inherited
-
Enabled:
Inherited
-
FeederID:
Inherited
-
ConstructionStatus:
Inherited
-
NominalVoltage:
Coded Values:
[100: 4.16 kV]
, [290: 14.4 kV]
, [330: 24.9 kV]
, ...1 more...
-
MaxContinuousCurrent:
Inherited
-
MaxInterruptingCurrent:
Inherited
-
MaxOperatingVoltage:
Inherited
-
NormalPosition_A:
Inherited
-
NormalPosition_B:
Inherited
-
NormalPosition_C:
Inherited
-
PresentPosition_A:
Inherited
-
PresentPosition_B:
Inherited
-
PresentPosition_C:
Inherited
-
PhaseDesignation:
Coded Values:
[7: ABC]
-
BILRating:
Inherited
-
BypassSwitch:
Coded Values:
[N: No]
, [Y: Yes]
-
GangOperated:
Coded Values:
[NA: Not Applicable]
-
InterruptingMedium:
Inherited
-
MountingType:
Coded Values:
[PAD: Pad Mounted]
, [POL: Pole Mounted]
, [SUB: Substation Frame]
-
ShuntMechanism:
Coded Values:
[NA: Not Applicable]
-
TieSwitchIndicator:
Coded Values:
[N: No]
, [Y: Yes]
-
TripCount:
Coded Values:
[0: Not Applicable]
ID: 3
Name: Single Phase Hydraulic Recloser
Domains:
-
AncillaryRole:
Inherited
-
Enabled:
Inherited
-
FeederID:
Inherited
-
ConstructionStatus:
Inherited
-
NominalVoltage:
Coded Values:
[100: 4.16 kV]
, [290: 14.4 kV]
, [330: 24.9 kV]
, ...1 more...
-
MaxContinuousCurrent:
Inherited
-
MaxInterruptingCurrent:
Inherited
-
MaxOperatingVoltage:
Inherited
-
NormalPosition_A:
Inherited
-
NormalPosition_B:
Inherited
-
NormalPosition_C:
Inherited
-
PresentPosition_A:
Inherited
-
PresentPosition_B:
Inherited
-
PresentPosition_C:
Inherited
-
PhaseDesignation:
Coded Values:
[4: A]
, [2: B]
, [1: C]
-
BILRating:
Inherited
-
BypassSwitch:
Coded Values:
[N: No]
, [Y: Yes]
-
GangOperated:
Coded Values:
[NA: Not Applicable]
-
InterruptingMedium:
Inherited
-
MountingType:
Coded Values:
[PAD: Pad Mounted]
, [POL: Pole Mounted]
, [SUB: Substation Frame]
-
ShuntMechanism:
Coded Values:
[NA: Not Applicable]
-
TieSwitchIndicator:
Coded Values:
[N: No]
, [Y: Yes]
-
TripCount:
Coded Values:
[0: Not Applicable]
ID: 2
Name: Fault Interrupter
Domains:
-
AncillaryRole:
Inherited
-
Enabled:
Inherited
-
FeederID:
Inherited
-
ConstructionStatus:
Inherited
-
NominalVoltage:
Coded Values:
[100: 4 kV]
, [190: 8 kV]
, [300: 15 kV]
, ...3 more...
-
MaxContinuousCurrent:
Inherited
-
MaxInterruptingCurrent:
Inherited
-
MaxOperatingVoltage:
Inherited
-
NormalPosition_A:
Inherited
-
NormalPosition_B:
Inherited
-
NormalPosition_C:
Inherited
-
PresentPosition_A:
Inherited
-
PresentPosition_B:
Inherited
-
PresentPosition_C:
Inherited
-
PhaseDesignation:
Coded Values:
[4: A]
, [6: AB]
, [5: AC]
, ...4 more...
-
BILRating:
Inherited
-
BypassSwitch:
Coded Values:
[NA: Not Applicable]
-
GangOperated:
Coded Values:
[N: No]
, [Y: Yes]
-
InterruptingMedium:
Inherited
-
MountingType:
Coded Values:
[NA: Not Applicable]
-
TieSwitchIndicator:
Coded Values:
[NA: Not Applicable]
-
Manufacturer:
Coded Values:
[BRI: Bridges]
, [SIE: Siemens]
, [OTH: Other]
, ...1 more...
ID: 7
Name: Three Phase Relay Recloser
Domains:
-
AncillaryRole:
Inherited
-
Enabled:
Inherited
-
FeederID:
Inherited
-
ConstructionStatus:
Inherited
-
NominalVoltage:
Coded Values:
[100: 4.16 kV]
, [290: 14.4 kV]
, [330: 24.9 kV]
, ...1 more...
-
MaxContinuousCurrent:
Inherited
-
MaxInterruptingCurrent:
Inherited
-
MaxOperatingVoltage:
Inherited
-
NormalPosition_A:
Inherited
-
NormalPosition_B:
Inherited
-
NormalPosition_C:
Inherited
-
PresentPosition_A:
Inherited
-
PresentPosition_B:
Inherited
-
PresentPosition_C:
Inherited
-
PhaseDesignation:
Coded Values:
[7: ABC]
-
BILRating:
Inherited
-
BypassSwitch:
Coded Values:
[N: No]
, [Y: Yes]
-
GangOperated:
Coded Values:
[NA: Not Applicable]
-
InterruptingMedium:
Inherited
-
MountingType:
Coded Values:
[PAD: Pad Mounted]
, [POL: Pole Mounted]
, [SUB: Substation Frame]
-
ShuntMechanism:
Coded Values:
[NA: Not Applicable]
-
TieSwitchIndicator:
Coded Values:
[N: No]
, [Y: Yes]
-
TripCount:
Coded Values:
[0: Not Applicable]
ID: 4
Name: Two Phase Hydraulic Recloser
Domains:
-
AncillaryRole:
Inherited
-
Enabled:
Inherited
-
FeederID:
Inherited
-
ConstructionStatus:
Inherited
-
NominalVoltage:
Coded Values:
[100: 4.16 kV]
, [290: 14.4 kV]
, [330: 24.9 kV]
, ...1 more...
-
MaxContinuousCurrent:
Inherited
-
MaxInterruptingCurrent:
Inherited
-
MaxOperatingVoltage:
Inherited
-
NormalPosition_A:
Inherited
-
NormalPosition_B:
Inherited
-
NormalPosition_C:
Inherited
-
PresentPosition_A:
Inherited
-
PresentPosition_B:
Inherited
-
PresentPosition_C:
Inherited
-
PhaseDesignation:
Coded Values:
[6: AB]
, [5: AC]
, [3: BC]
-
BILRating:
Inherited
-
BypassSwitch:
Coded Values:
[N: No]
, [Y: Yes]
-
GangOperated:
Coded Values:
[NA: Not Applicable]
-
InterruptingMedium:
Inherited
-
MountingType:
Coded Values:
[PAD: Pad Mounted]
, [POL: Pole Mounted]
, [SUB: Substation Frame]
-
ShuntMechanism:
Coded Values:
[NA: Not Applicable]
-
TieSwitchIndicator:
Coded Values:
[N: No]
, [Y: Yes]
-
TripCount:
Coded Values:
[0: Not Applicable]
ID: 1
Name: Circuit Breaker
Domains:
-
AncillaryRole:
Inherited
-
Enabled:
Inherited
-
FeederID:
Inherited
-
ConstructionStatus:
Inherited
-
NominalVoltage:
Coded Values:
[100: 4 kV]
, [190: 8 kV]
, [300: 15 kV]
, ...3 more...
-
MaxContinuousCurrent:
Inherited
-
MaxInterruptingCurrent:
Inherited
-
MaxOperatingVoltage:
Inherited
-
NormalPosition_A:
Inherited
-
NormalPosition_B:
Inherited
-
NormalPosition_C:
Inherited
-
PresentPosition_A:
Inherited
-
PresentPosition_B:
Inherited
-
PresentPosition_C:
Inherited
-
PhaseDesignation:
Coded Values:
[4: A]
, [6: AB]
, [5: AC]
, ...4 more...
-
BILRating:
Inherited
-
BypassSwitch:
Coded Values:
[N: No]
, [Y: Yes]
-
GangOperated:
Coded Values:
[NA: Not Applicable]
-
InterruptingMedium:
Inherited
-
MountingType:
Coded Values:
[NA: Not Applicable]
-
ShuntMechanism:
Coded Values:
[NA: Not Applicable]
-
TieSwitchIndicator:
Coded Values:
[NA: Not Applicable]
-
TripCount:
Coded Values:
[0: Not Applicable]
-
Manufacturer:
Coded Values:
[ABB: ABB/Westinghouse]
, [BB: Brown Boveri]
, [CPR: Cooper/McGraw Edison]
, ...4 more...
Supported Operations:
Query
Query Attachments
Query Analytic
Generate Renderer
Return Updates
Iteminfo
Thumbnail
Metadata