Description: Overhead electric line segments carry electric current and are supported by structures including power poles, H-frames, and towers. The PriOHElectricLineSegment class inherits the attributes of ElectricComplexEdge and ElectricLineSegment.The CONDUCTOR model name designates the feature class as a conductor. This is part of the basic ArcFM configuration.The DESIGNBANK model name is used by the Work Function tool in Designer. It designates a banked feature in the network.The ELECTRICNETWORKEDGE model name is used to configure electric tracing in ArcFM Viewer for ArcGIS Engine. Assign to all Electric Network Edge feature classes that participate in electric tracing.Structural Analysis uses the OVERHEADCONDUCTOR model name.The PRIMARYCONDUCTOR model name is used by Structural Analysis as well as the Phase on Transformer Bank QA Validation rule. It is also used by the ArcFM Inherit Nominal Voltage and ArcFM Inherit Operating Voltage autoupdaters.The ArcFM Segment Split autoupdater requires that the linear feature have the SPLITTARGET model name assigned. When a point feature (with this AU assigned) is placed on a linear feature, this AU looks for the SPLITTARGET model name. If it exists, it splits the line into two features and snaps the point feature between the two new linear features.PrimaryOverheadElectricLineSegment inherits attributes from the ElectricLineSegment abstract class. Any model names assigned to ElectricLineSegment should also be assigned to the PrimaryOverheadElectricLineSegment class.
Color: [0, 0, 0, 255] Background Color: N/A Outline Color: N/A Vertical Alignment: bottom Horizontal Alignment: center Right to Left: false Angle: 0 XOffset: 0 YOffset: 0 Size: 8 Font Family: Arial Font Style: normal Font Weight: normal Font Decoration: none
Description: Primary URD cables are usually single-conductor, concentric-neutral insulated with polyethylene or cross-linked polyethylene. Utilities may direct-bury primary cables in the same trench as communication cables.The CONDUCTOR model name designates the feature class as a conductor. This is part of the basic ArcFM configuration.The DESIGNBANK model name is used by the Work Function tool in Designer. It designates a banked feature in the network.The ELECTRICNETWORKEDGE model name is used to configure electric tracing in ArcFM Viewer for ArcGIS Engine. Assign to all Electric Network Edge feature classes that participate in electric tracing.The PRIMARYCONDUCTOR model name is used by the Phase on Transformer Bank QA Validation rule. It is also used by the ArcFM Inherit Nominal Voltage and ArcFM Inherit Operating Voltage autoupdaters.The ArcFM Segment Split autoupdater requires that the linear feature have the SPLITTARGET model name assigned. When a point feature (with this AU assigned) is placed on a linear feature, this AU looks for the SPLITTARGET model name. If it exists, it splits the line into two features and snaps the point feature between the two new linear features.Conduit Manager uses the ULSMEMBER model name to designate the PrimaryUndergroundElectricLineSegment feature class as an edge that can be found within a conduit.PrimaryUndergroundElectricLineSegment inherits attributes from the ElectricLineSegment abstract class. Any model names assigned to ElectricLineSegment should also be assigned to the PrimaryUndergroundElectricLineSegment class.
Color: [0, 0, 0, 255] Background Color: N/A Outline Color: N/A Vertical Alignment: bottom Horizontal Alignment: center Right to Left: false Angle: 0 XOffset: 0 YOffset: 0 Size: 8 Font Family: Arial Font Style: normal Font Weight: normal Font Decoration: none
Description: Overhead electric line segments carry electric current and are supported by structures including power poles, H-frames, and towers. The SecOHElectricLineSegment class inherits the attributes of ElectricComplexEdge and ElectricLineSegment.The CONDUCTOR model name designates the feature class as a conductor. This is part of the basic ArcFM configuration.The DESIGNBANK model name is used by the Work Function tool in Designer. It designates a banked feature in the network.The ELECTRICNETWORKEDGE model name is used to configure electric tracing in ArcFM Viewer for ArcGIS Engine. Assign to all Electric Network Edge feature classes that participate in electric tracing.Secondary Circuit Analysis in Designer uses the FEEDERSECONDARY model name.Structural Analysis uses the OVERHEADCONDUCTOR model name.The ArcFM Segment Split autoupdater requires that the linear feature have the SPLITTARGET model name assigned. When a point feature (with this AU assigned) is placed on a linear feature, this AU looks for the SPLITTARGET model name. If it exists, it splits the line into two features and snaps the point feature between the two new linear features.SecondaryOverheadElectricLineSegment inherits attributes from the ElectricLineSegment abstract class. Any model names assigned to ElectricLineSegment should also be assigned to the SecondaryOverheadElectricLineSegment class.
Color: [0, 0, 0, 255] Background Color: N/A Outline Color: N/A Vertical Alignment: bottom Horizontal Alignment: center Right to Left: false Angle: 0 XOffset: 0 YOffset: 0 Size: 8 Font Family: Arial Font Style: normal Font Weight: normal Font Decoration: none
Description: Secondaries and services are usually served by three cables insulated with polyethylene that may be separate cables or triplex construction.The CONDUCTOR model name designates the feature class as a conductor. This is part of the basic ArcFM configuration.The DESIGNBANK model name is used by the Work Function tool in Designer. It designates a banked feature in the network.The ELECTRICNETWORKEDGE model name is used to configure electric tracing in ArcFM Viewer for ArcGIS Engine. Assign to all Electric Network Edge feature classes that participate in electric tracing.Secondary Circuit Analysis in Designer uses the FEEDERSECONDARY model name.The ArcFM Segment Split autoupdater requires that the linear feature have the SPLITTARGET model name assigned. When a point feature (with this AU assigned) is placed on a linear feature, this AU looks for the SPLITTARGET model name. If it exists, it splits the line into two features and snaps the point feature between the two new linear features.Conduit Manager uses the ULSMEMBER model name to designate the SecondaryUndergroundElectricLineSegment feature class as an edge that can be found within a conduit.SecondaryUndergroundElectricLineSegment inherits attributes from the ElectricLineSegment abstract class. Any model names assigned to ElectricLineSegment should also be assigned to the SecondaryUndergroundElectricLineSegment class.
Color: [0, 0, 0, 255] Background Color: N/A Outline Color: N/A Vertical Alignment: bottom Horizontal Alignment: center Right to Left: false Angle: 0 XOffset: 0 YOffset: 0 Size: 8 Font Family: Arial Font Style: normal Font Weight: normal Font Decoration: none
Description: Span guys are installed to span from the top of one structure or pole to the other and offset the strain from the line conductor. Span guys transmit horizontal force to another pole until an anchor guy can be used. SpanGuy is a linear feature and inherits attributes of Guy and Structure abstract classes.The Structural Analysis tool uses Span Guys while evaluating the amount of guy support necessary for a given support structure.The SpanGuy class inherits attributes from the Guy and Structure abstract classes. Model names assigned to these classes should be assigned to the SpanGuy class as well.